Description
Huawei AC650-256AP Wireless Access Controller Kuwait
The Huawei AC650-256AP Kuwait is an advanced wireless access controller (AC) engineered by Huawei to specifically address the demands of small and medium-sized enterprise (SME) network markets. This cutting-edge device is expertly designed to work in perfect harmony with Huawei access points (APs), enabling the creation of dependable and efficient wireless networks. It is particularly well-suited for environments such as small campus networks, the office networks of smaller enterprises, and areas in need of comprehensive hotspot coverage.
The Huawei AC650-256AP Kuwait is equipped with the capability to manage up to 256 access points, ensuring that network performance and connectivity remain strong and reliable. In addition to this, it can support access for up to 2048 simultaneous stations (STAs), which allows it to provide extensive coverage and maintain stable connections across a wide range of devices. This makes it an ideal solution for enterprises looking to establish or enhance their wireless network infrastructure with a focus on reliability and scalability.
Technical Specifications
Description | AC650-256AP mainframe (10*GE ports, 2*10GE SFP+ ports, with the AC/DC adapter) |
Part Number | 02355NCH |
Model | AC650-256AP |
First supported version | V200R022C10 |
Installation Type |
|
Dimensions without packaging (H x W x D) [mm(in.)] | Basic: 43.6 mm x 250 mm x 210 mm (1.72 in. x 9.84 in. x 8.27 in.)
Maximum: 43.6 mm x 250 mm x 215 mm (1.72 in. x 9.84 in. x 8.46 in.) |
Weight without packaging [kg(lb)] | 1.9kg |
Storage | Nand FLASH 1GB |
Console port | RJ45 |
Maximum power consumption [W] | 23.58 W |
Maximum heat dissipation [BTU/hour] | 80.45 BTU/hour |
Power supply mode | DC adapter |
Service port surge protection | 6 kV in common mode |
Types of fans | None |
Maximum number of physical ports on the entire device | 2 x 10GE (SFP+) + 10 x GE (RJ45) |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) (If the altitude is in the range of 1800 m to 5000 m, the temperature decreases by 1°C or 1.8°F every time the altitude increases by 300 m.) |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | –60 m to +5000 m (–196.85 ft to +16404.20 ft) |
Atmospheric pressure [kPa] | 53kPa – 106kPa ETSI 300 019-2-3 |
Ground | Ground |
USB | 1 x USB 2.0 (host type A) port |
MTBF [year] | 50 year |
MTTR [hour] | 2 hour |