Description
Huawei S310-48T4X Network Switch Kuwait
The Huawei S310-48T4X Kuwait fixed Ethernet switches offer a seamless integration of both access and transmission functionalities, delivering dependable access, aggregation, and high-quality service transmission for enterprise networks. These switches are engineered on a robust and unified hardware platform, which encompasses crucial components such as the chassis, power module, fan module, and the Switch Control Unit (SCU).
Specifically designed as unmanaged switches, the Huawei S310-48T4X Kuwait models forego web-based management interfaces and SNMP-based management capabilities. This design approach prioritizes simplicity, user-friendliness, and straightforward deployment, making them an ideal solution for environments where minimal configuration and low maintenance are essential. As a result, network administrators benefit from a hassle-free experience, ensuring that the switches deliver efficient performance without the complexities often associated with more advanced network management features.
Technical Specifications
Description | S310-48T4X (48*10/100/1000BASE-T ports, 4*10GE SFP+ ports, built-in AC power) |
Part Number | 98012383 |
Model | S310-48T4X |
First supported version | V600R023C00 |
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.)
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) |
Chassis height [U] | 1 U |
Chassis material | Metal |
Weight without packaging [kg(lb)] | 2.71 kg (5.97 lb) |
Weight with packaging [kg(lb)] | 3.59 kg (7.91 lb) |
Typical power consumption [W] | 36.95 W |
Typical heat dissipation [BTU/hour] | 126.07 BTU/hour |
Maximum power consumption [W] | 44.3 W |
Maximum heat dissipation [BTU/hour] | 151.15 BTU/hour |
Static power consumption | 18.8 |
MTBF [years] | 40.61 years |
MTTR [hours] | 2 hours |
Availability | > 0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 46.6 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 34.6 dB(A) |
Number of card slots | 0 |
Number of power slots | 0 |
Number of fans modules | 1 |
Switching capacity | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
Packet forwarding rate | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
Redundant power supply | Not supported |
Long-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Devices cannot start when the temperature is lower than 0°C (32°F). The operating temperature ranges from –5°C (23°F) to +45°C (113°F) when optical modules with transmission distances greater than or equal to 60 km are used. The device does not support dying gasp when the ambient temperature is higher than 40°C (104°F). |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | AC built-in |
Rated input voltage [V] | AC input: 100–240 V AC; 50/60 Hz |
Input voltage range [V] | AC input: 90 V AC to 264 V AC; 45 Hz to 65 Hz |
Maximum input current [A] | 1.6 A |
Memory | 2 GB |
Flash memory | Physical space: 1 GB |
Console port | RJ45 |
Eth Management port | Not supported |
USB | Not supported |
RTC | Not supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection [kV] | Differential mode: ±6 kV; common mode: ±6 kV |
Ingress protection level (dustproof/waterproof) | IP20 |
Types of fans | Built-in |
Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction | Air intake from left and air exhaust from right |
PoE | Not supported |
Certification |
|